What the equipment in Hollywood can and cannot remove
Original ductwork is the defining piece of equipment in Hollywood, because the cooling has been replaced two or three times since 1969 and the duct almost never has. What that produces is a modern, efficient condenser and air handler blowing into a distribution system designed for a different machine, with insulation that has aged out and joints that have opened. In the beachside blocks the picture is different again: through-wall and packaged terminal units serving one room each, with no whole-house dehumidification anywhere in the building and a wall sleeve detailed half a century ago.
The reason that matters is a gap between two numbers, both from the Florida Solar Energy Center at the University of Central Florida. Through the hot months, with cooling running, indoor relative humidity should not exceed 55% during the day on a regular basis. And the great majority of mold species need a material moisture content corresponding to a relative humidity of at least 70% to grow at all.
Note where that second number is measured. Not in the room. At the material. Air holds less moisture as it cools, so the film of air against a chilled surface sits at a far higher relative humidity than the room average. A wall at 68F with 78F room air at 55% is close to saturation at its own face, and it does not need a leak to get there. That is the mechanism behind almost every complaint where nobody can find a source.
So in Hollywood we read surface temperatures with an infrared thermometer alongside the room air, calculate the dew point of that air, and record the margin at every surface that has one worth recording. FSEC also give the point at which cooling alone stops being enough: sustained readings of 70 to 75% mean dehumidification rather than a colder thermostat, and turning the thermostat down at that stage chills the surfaces further and makes it worse.
The commercial position in Hollywood is the one published on every page of this site, because the rate card is not a Fort Lauderdale rate card. A flat price by property size, agreed before anyone drives out, with the accredited laboratory fee already inside it. It does not rise if the samples come back positive, nothing is added for the drive, and we take no payment of any kind from anyone who removes mold.

What Hollywood itself changes
The buildings in Hollywood
Hollywood has a median build year of 1969 across 72,843 housing units, which places most of the city in the first generation of Florida housing designed around central air conditioning from the outset rather than having it retrofitted later. That sounds like an advantage and it cuts both ways. These houses were designed to be cooled, so the envelope is tighter than the pre-war stock further south, but they were designed to a 1960s understanding of it: ducts sized generously, equipment specified by rule of thumb, and very little attention paid to what happens to humidity when the machine is satisfied early. Forty-three per cent of the stock is single-family detached and another 19% sits in buildings of fifty units or more, so the city carries both the single-storey slab house and the mid-century beachside block, and those two fail in completely different ways.
Where the water comes from
Hollywood sits inside the footprint of the April 2023 rainfall event, the one that put 25.91 inches on this coastline in 24 hours against a previous record of 14.59 set in 1979. That matters here for a specific reason: the older eastern parts of the city sit on a street grid laid out long before modern stormwater design, so water that arrives faster than the system can take it stands rather than drains. Add the ordinary wet season, 47.27 of the 66.52 inches this coast averages arriving between May and October, and a good share of the calls we take in Hollywood are about a building that took water once and was dried in a hurry.
Where it hides in these buildings
The 1960s single-storey stock here puts almost everything that matters out of sight in two places. The first is the attic, where the air handler frequently sits along with duct runs that were insulated to the standard of the day and have had sixty years to compress, slip or split. The second is the slab edge, where a terrazzo or tiled floor meets an exterior block wall, which on a house of this era has no capillary break worth the name. Growth at a wall base behind furniture is the commonest Hollywood finding and it is invisible until something is moved.